Made with FlowPaper - Flipbook Maker
PERSPECTIVES IAQ and sensors Stacey Lucas, Sontay Steam rooms and condensation Alican Aykaç, Sauna Dekor Spa Solutions Protecting CHW plants Bryan Monds, Chiller Core Solutions UAE MARKET UPDATE Recovery on the horizon for VRFs, splits, chillers TABREED 9M REPORT: INCREASE IN CONNECTED CAPACITY TO 1.59 MILLION RT EMPOWER 9M REPORT: 10.6% GROWTH IN NET PROFIT, REVENUE REACHES AED 2.71 BILLION November 2026 NEWS CG Power and Industrial Solutions launches AMX Series drives Copernicus: Warmest October on record with 2026 virtually certain to exceed 1.5 degrees C RAK Energy Summit (3 rd Edition) to spotlight energy security, competitiveness, sustainability Veolia signs desalination contracts in the Middle East US$ PUBLICATION LICENSED BY IMPZ US$ PUBLICATION LICENSED BY IMPZ US$ PUBLICATION LICENSED BY IMPZ US$ PUBLICATION LICENSED BY IMPZ ccme.news/digital AMPING UP RELIABILITY THE IMPORTANCE OF TRUSTWORTHY MEASUREMENTS IN OPERATING LIQUID-COOLED DATA CENTRES1206 VOL. 21 NO. 11 NOVEMBER 2026 12 16 10 06 www.ccme.news 3 REGULARS Regional News Global News eDItor'S note Measure, protect In an environment of rapidly increasing rack densities, absence of trustworthy measurements could condemn liquid-cooled data centres to operate on assumptions, says Anu Kätkä of Vaisala 18 PERSPECTIVES ‘Are we sensing IAQ effectively?’ A sensor may meet its stated accuracy specification but still provide information that does not reflect the conditions experienced by occupants, says Stacey Lucas of Sontay Why the steam room is the hardest boundary in a cooled building Alican Aykaç of Sauna Dekor Spa Solutions addresses the building physics of condensation in spas in the GCC region ‘Most chiller plants don't fail suddenly’ Bryan Monds of Chiller Core Solutions elaborates on what 20+ years of chiller service has taught him about plant reliability 04 22 30 24 MARKET UPDATE BSRIA: ‘USD 1.08 bn UAE split, VRF and chiller market by 2030’ A 2026 update indicates near-term softness in unit sales before a recovery from 2028 Friction so thick you could cut it with a knife COVER STORYNovember 2026 4 A s a rather tumultuous year winds up, I find myself pondering over the extent we have progressed as an industry serving comfort cooling and industrial cooling needs. Progress is inextricably linked to friction and is measured on the basis of the sheer force we apply to overcome elements that cause inertia. The year has thrown up a few frictional elements that have, in fact, threated to stall the march forward; some might argue, we have regressed. From a geopolitical perspective, it’s been a year that has thrown a fresh set of challenges that have massively impacted the Middle East region. Manufacturers and suppliers I have spoken to have repeatedly pointed to supply chain disruptions, with two clear-cut periods. The first was from March to May, when goods were regularly stranded in ports afar, because ships to the region cancelled their voyages altogether, forcing equipment businesses to shift their thinking from strategic to operational activities. The second was from June to September, when the situation improved – though 40-foot containers coming to the UAE remained priced at USD 6,500, as opposed to the pre-war cost of USD 500. So, how exactly did the situation improve? Simply because there were businesses that pivoted and innovated their way to relative stability. One operator spoke of being opportunistic, thriving on the fact that project owners stopped demanding specific brands, as long as they received any brand of equal acceptable quality to ensure their projects did not stall. And therein lies a tale. And what of Sustainable Development as an indicator of progress in the year? One supplier I interviewed a couple of months ago said it was no longer a priority. “My focus is on getting my goods to port,” he said. “At this moment, I am not thinking of sustainable development.” And what of legacy frictional elements? Sustainable Development itself has been at the centre of attention, with a dominant majority rather limiting its definition to energy efficiency and water-use optimisation in the context of building performance. Advocates of Indoor Environmental Quality for long have called for inclusion, but progress has been slow, if at all, with one reason stated as lack of tools to measure impact of interventions, which would help establish ROI. True, this area needs to be addressed, but at the same time, we need regulation to support the inclusion of IAQ in intense pre-design discussions. For instance, why mandate IAQ monitoring only during commissioning? Why not establish a regime of continuous monitoring across the lifecycle of a building. It is important to break down barriers to accelerate adoption. Krishnan Unni Madathil Auditor, Bin Khadim, Radha & Co. Chartered Accountants, carrying out an analysis of the market, writes on business opportunities for the HVACR industry. Dan Mizesko LTC expert, writes on issues relating to chilled water systems, including operation & maintenance. Nabil Shahin Managing Director, AHRI MENA, writes on HVACR- specific regulation issues. Dr Iyad Al-Attar Independent air filtration consultant, writes on specific science and technology issues relating to Indoor Air Quality, including airborne particles. Angela Fandino Director, Energy Sustainability at Engineering Sustainable Futures, writes on engineering approaches, and business and financial models that enable a green urban ecosystem. Editor Surendar Balakrishnan surendar@cpi-industry.com Associate Editor Karu Suren karu.suren@cpi-industry.com Online & Social Media Abdul Hakeem marketing@cpi-industry.com Design Head Ulysses Galgo design@cpi-industry.com Webmaster Chris Lopez chris@cpi-industry.com Editorial Assistant Arushi Menon features@cpi-industry.com Advertising Enquiries Frédéric Paillé +971 50 7147204 fred@cpi-industry.com Deep Karani Our representative in North America +1 365 885-6849 deep.karani@cpimediagroup.com Database/Subscriptions Manager Purwanti Srirejeki purwanti@cpi-industry.com Published by Founder, CPI Media Group Dominic De Sousa (1959-2015) Co-Founder & Commercial Director Frédéric Paillé fred@cpi-industry.com EMPANELLED COLUMNISTS Co-Founder & Editorial Director Surendar Balakrishnan surendar@cpi-industry.com Head Office PO Box 13700, Dubai, UAE Web: www.cpi-industry.com Printed by: Wellpack Printing Press LLC, Ajman, UAE © Copyright 2026 CPI Industry. All rights reserved. While the publishers have made every effort to ensure the accuracy of all information in this magazine, they will not be held responsible for any errors therein. Visit our website: climatecontrolme.com/digital Also available at Get the next issue of Climate Control Middle Eastearly! Surendar Balakrishnan Editor @BSurendar_HVACR Friction so thick you could cut it with a knifeNovember 2026 6 PERSPECTIVE A S BUILDINGS become more connected, sensing technology is playing an increasingly important role in how we understand and manage indoor environments. From temperature and humidity through to carbon dioxide (CO 2 ), particulate matter and volatile organic compounds (VOCs), building operators now have access to a broader range of environmental information. With this greater access to data comes a responsibility to ensure that what we measure is accurate, representative and useful. There is growing recognition of the relationship among Indoor Air Quality (IAQ), occupant wellbeing and building performance. However, several important questions remain about how effectively we monitor these conditions and how the information collected is used. Are we sensing reliably? Sensor technology has advanced considerably, offering improved accuracy, connectivity and the ability to monitor multiple environmental parameters. Nevertheless, reliable measurement depends on more than the specification of the device. Accuracy, calibration, long-term stability and maintenance all influence sensor performance. Environmental conditions and sensor drift can also affect readings over time, making regular verification important. A sensor may meet its stated accuracy specification but still provide information that does not reflect the conditions experienced by occupants. For building operators, reliable monitoring requires an understanding of the technology being installed, its limitations and the maintenance needed to sustain performance throughout the building’s operational life. The basis for sensor placement for accurate readings Sensor positioning is one of the most important considerations in any IAQ monitoring strategy. Within a single building, environmental conditions can vary considerably. Meeting rooms, offices, corridors and reception areas may share the same ventilation system but experience different occupancy levels, activities and pollutant sources. A meeting room occupied by several people may experience rising CO 2 concentrations, while an adjacent corridor remains relatively unaffected. Reception areas may be influenced by external air entering through frequently opened doors, while office spaces can be affected by cleaning products, furnishings or equipment. These differences mean that a single sensor cannot always provide an accurate picture of conditions across an entire floor or building. The location of each sensor should reflect the purpose of the measurement and the characteristics of the space. Sensors positioned directly beside supply-air diffusers, windows, external doors or local pollutant sources may produce readings that are not representative of the wider occupied area. Consideration should also be given to occupancy patterns, airflow distribution, mounting height and accessibility for maintenance. For consulting engineers and building operators, understanding these factors at the design stage can make a considerable difference to the quality of information available throughout the building's life. Are cabling costs determining the placement of sensors? In practice, sensor positioning is not always determined by environmental considerations alone. Installation costs, cabling routes, containment and access requirements can influence where devices are installed, particularly within existing buildings. Wired sensing remains an established and reliable solution for A sensor may meet its stated accuracy specification but still provide information that does not reflect the conditions experienced by occupants, says Stacey Lucas of SontayWe bring it all together.November 2026 8 building management systems, offering continuous connectivity and integration with control infrastructure. However, extending cabling into occupied spaces can present challenges, especially in refurbishment projects, heritage buildings and environments where disruption must be minimised. Wireless sensing provides an additional option, allowing monitoring points to be introduced without extensive new cabling. This flexibility can be particularly useful where environmental conditions vary across a building or where additional monitoring is required following changes in occupancy or space utilisation. The choice between wired and wireless technology should consider the application, communication reliability, maintenance requirements and existing building infrastructure. Sensor positioning should be guided by the information required to manage the space effectively, rather than installation convenience alone. Can five spaces in the same building have different IAQ? Even where spaces share the same HVAC system, their IAQ can differ significantly. Occupancy density, ventilation effectiveness, door movements, equipment and local pollutant sources all influence environmental conditions. CO 2 monitoring has become increasingly common, particularly as awareness of ventilation and Indoor Environmental Quality (IEQ) has grown. While CO 2 provides useful information about ventilation relative to occupancy, it does not represent every aspect of IAQ. Particulate matter, VOCs, humidity and other contaminants can influence indoor conditions independently of CO 2 concentrations. For example, a space may maintain acceptable CO 2 levels while experiencing elevated particulate concentrations from outdoor pollution or internal activities. Monitoring several environmental parameters provides building operators with a more complete understanding of conditions and helps identify where further investigation may be required. When connected to a building energy management system (BEMS), this information can support ventilation control, trend analysis and operational improvements. What happens after sensing? Collecting environmental data is only one part of managing IAQ. Once a potential issue has been identified, building operators need a clear process for investigating the cause and determining the appropriate response. This requires cooperation among building owners, facilities managers, consultants and controls specialists, with defined responsibilities for monitoring, maintenance and corrective action. Elevated CO 2 concentrations may indicate that ventilation provision needs reviewing. Particulate pollution may require an assessment of filtration performance, outdoor air intake conditions or internal pollutant sources. Where gaseous contaminants are identified, source control, ventilation adjustments or appropriate gas-phase filtration may be necessary. Ongoing monitoring can then help determine whether the measures introduced have improved conditions. IAQ governance Effective IAQ governance requires a structured approach to identifying environmental risks, establishing performance objectives and implementing appropriate interventions. Filtration technologies should be selected according to the pollutants being addressed, the capabilities of the ventilation system and the building's operational requirements. For example, particulate filtration and gas-phase filtration serve different purposes. Increasing filter efficiency without considering airflow resistance, fan capacity and maintenance requirements may introduce additional operational challenges. Building operators should establish responsibilities for reviewing IAQ data, investigating persistent issues, maintaining filtration systems and verifying performance following corrective action. This is particularly important as buildings change over time. Occupancy patterns evolve, spaces are repurposed and ventilation systems require maintenance and adjustment. A clear governance framework ensures that environmental monitoring informs ongoing building management rather than simply generating reports. Supporting better building performance As expectations surrounding healthier, more efficient buildings continue to develop, the importance of reliable environmental monitoring will increase. The wider opportunity for the industry lies in considering sensing technology as part of a building's long-term operational strategy. With appropriate sensor selection, positioning and integration, environmental data can support more informed decisions about ventilation, filtration, energy performance and occupant comfort. The effectiveness of any monitoring strategy ultimately depends on the accuracy of the information collected and how that information is used to improve the indoor environment. CPI Industry accepts no liability for the views or opinions expressed in this article, or for the consequences of any actions taken on the basis of the information provided here. The writer is Commercial & Marketing Director, Sontay. She may be contacted at <stacey.lucas@sontay.com>. PERSPECTIVEPRESENTS 2026 14 DECEMBER I DUBAI, UAE www.climatecontrolawards.com/uae ccme.news/digital MONITORED BY ASSOCIATE SPONSORS CATEGORY SPONSORBRONZE SPONSOR OFFICIAL PUBLICATIONSTRATEGIC HVACR RECRUITMENT PARTNER OFFICIAL BROADCAST TV CHANNELNext >